tee (1)
PROLOG
This manual page is part of the POSIX Programmer's Manual. The Linux implementation of this interface may differ (consult the corresponding Linux manual page for details of Linux behavior), or the interface may not be implemented on Linux.NAME
tee --- duplicate standard inputSYNOPSIS
tee [-ai] [file...]
DESCRIPTION
The tee utility shall copy standard input to standard output, making a copy in zero or more files. The tee utility shall not buffer output. If the -a option is not specified, output files shall be written (see Section 1.1.1.4, File Read, Write, and Creation.OPTIONS
The tee utility shall conform to the Base Definitions volume of POSIX.1-2008, Section 12.2, Utility Syntax Guidelines. The following options shall be supported:- -a
- Append the output to the files.
- -i
- Ignore the SIGINT signal.
OPERANDS
The following operands shall be supported:- file
- A pathname of an output file. If a file operand is '-', it shall refer to a file named -; implementations shall not treat it as meaning standard output. Processing of at least 13 file operands shall be supported.
STDIN
The standard input can be of any type.INPUT FILES
None.ENVIRONMENT VARIABLES
The following environment variables shall affect the execution of tee:- LANG
- Provide a default value for the internationalization variables that are unset or null. (See the Base Definitions volume of POSIX.1-2008, Section 8.2, Internationalization Variables for the precedence of internationalization variables used to determine the values of locale categories.)
- LC_ALL
- If set to a non-empty string value, override the values of all the other internationalization variables.
- LC_CTYPE
- Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed to multi-byte characters in arguments).
- LC_MESSAGES
-
Determine the locale that should be used to affect the format and contents of diagnostic messages written to standard error. - NLSPATH
- Determine the location of message catalogs for the processing of LC_MESSAGES.
ASYNCHRONOUS EVENTS
Default, except that if the -i option was specified, SIGINT shall be ignored.STDOUT
The standard output shall be a copy of the standard input.STDERR
The standard error shall be used only for diagnostic messages.OUTPUT FILES
If any file operands are specified, the standard input shall be copied to each named file.EXTENDED DESCRIPTION
None.EXIT STATUS
The following exit values shall be returned:- 0
- The standard input was successfully copied to all output files.
- >0
- An error occurred.
CONSEQUENCES OF ERRORS
If a write to any successfully opened file operand fails, writes to other successfully opened file operands and standard output shall continue, but the exit status shall be non-zero. Otherwise, the default actions specified in Section 1.4, Utility Description Defaults apply.The following sections are informative.
APPLICATION USAGE
The tee utility is usually used in a pipeline, to make a copy of the output of some utility. The file operand is technically optional, but tee is no more useful than cat when none is specified.EXAMPLES
Save an unsorted intermediate form of the data in a pipeline:
-
... | tee unsorted | sort > sorted
RATIONALE
The buffering requirement means that tee is not allowed to use ISO C standard fully buffered or line-buffered writes. It does not mean that tee has to do 1-byte reads followed by 1-byte writes. It should be noted that early versions of BSD ignore any invalid options and accept a single '-' as an alternative to -i. They also print a message if unable to open a file:
-
"tee: cannot access %s\n", <pathname>
FUTURE DIRECTIONS
None.SEE ALSO
Chapter 1, Introduction, cat The Base Definitions volume of POSIX.1-2008, Chapter 8, Environment Variables, Section 12.2, Utility Syntax Guidelines The System Interfaces volume of POSIX.1-2008, lseek()COPYRIGHT
Portions of this text are reprinted and reproduced in electronic form from IEEE Std 1003.1, 2013 Edition, Standard for Information Technology -- Portable Operating System Interface (POSIX), The Open Group Base Specifications Issue 7, Copyright (C) 2013 by the Institute of Electrical and Electronics Engineers, Inc and The Open Group. (This is POSIX.1-2008 with the 2013 Technical Corrigendum 1 applied.) In the event of any discrepancy between this version and the original IEEE and The Open Group Standard, the original IEEE and The Open Group Standard is the referee document. The original Standard can be obtained online at www.unix.org/online.html .Any typographical or formatting errors that appear in this page are most likely to have been introduced during the conversion of the source files to man page format. To report such errors, see www.kernel.org/doc/man-pages/reporting_bugs.html .