profcheck (1)
NAME
Check - Check accuracy of ICC profile.
DESCRIPTION
Check accuracy of ICC profile, Version 1.6.3
SYNOPSIS
profcheck
[-options] data.ti3 iccprofile.icm
- -v [level]
-
Verbosity level (default 1), 2 to print each DE
- -c
-
Show CIE94 delta E values
- -k
-
Show CIEDE2000 delta E values
- -w
-
create VRML visualisation (iccprofile.wrl)
- -x
-
Use VRML axes
- -m
-
Make VRML lines a minimum of 0.5
- -e
-
Color vectors according to delta E
-
-d devval1,deval2,devvalN
-
- Specify a device value to sort against
- -p
-
Sort device value by PCS (Lab) target
- -f [illum]
-
Use Fluorescent Whitening Agent compensation [opt. simulated inst. illum.:
-
M0, M1, M2, A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp]
- -i illum
-
Choose illuminant for computation of CIE XYZ from spectral data & FWA:
-
A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
- -o observ
-
Choose CIE Observer for spectral data:
-
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
- -I intent
-
r = relative colorimetric, a = absolute (default)
- data.ti3
-
Test data file
- iccprofile.icm
-
Profile to check against