chartread -V (return code: 1)
Read Target Test Chart, Version 1.8.3
Author: Graeme W. Gill, licensed under the AGPL Version 3
usage: chartread [-options] outfile
-v Verbose mode
-c listno Set communication port from the following list (default 1)
1 = '/dev/ttyS0'
2 = '/dev/ttyS1'
3 = '/dev/ttyS10'
4 = '/dev/ttyS11'
5 = '/dev/ttyS12'
6 = '/dev/ttyS13'
7 = '/dev/ttyS14'
8 = '/dev/ttyS15'
9 = '/dev/ttyS16'
10 = '/dev/ttyS17'
11 = '/dev/ttyS18'
12 = '/dev/ttyS19'
13 = '/dev/ttyS2'
14 = '/dev/ttyS20'
15 = '/dev/ttyS21'
16 = '/dev/ttyS22'
17 = '/dev/ttyS23'
18 = '/dev/ttyS24'
19 = '/dev/ttyS25'
20 = '/dev/ttyS26'
21 = '/dev/ttyS27'
22 = '/dev/ttyS28'
23 = '/dev/ttyS29'
24 = '/dev/ttyS3'
25 = '/dev/ttyS30'
26 = '/dev/ttyS31'
27 = '/dev/ttyS4'
28 = '/dev/ttyS5'
29 = '/dev/ttyS6'
30 = '/dev/ttyS7'
31 = '/dev/ttyS8'
32 = '/dev/ttyS9'
-t Use transmission measurement mode
-d Use display measurement mode (white Y relative results)
-y l|c Other: l = LCD, c = CRT
-e Emissive for transparency on a light box
-p Measure patch by patch rather than strip
-x [lx] Take external values, either L*a*b* (-xl) or XYZ (-xx).
-n Don't save spectral information (default saves spectral)
-l Save CIE as D50 L*a*b* rather than XYZ
-L Save CIE as D50 L*a*b* as well as XYZ
-r Resume reading partly read chart
-I file.cal Override calibration info from .ti2 in resulting .ti3
-F filter Set filter configuration (if aplicable):
n None
p Polarising filter
6 D65
u U.V. Cut
-N Disable initial calibration of instrument if possible
-B Disable auto bi-directional strip recognition
-H Use high resolution spectrum mode (if available)
-X file.ccmx Apply Colorimeter Correction Matrix
-X file.ccss Use Colorimeter Calibration Spectral Samples for calibration
-Q observ Choose CIE Observer for CCSS instrument:
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
-T ratio Modify strip patch consistency tolerance by ratio
-S Suppress wrong strip & unexpected value warnings
-W n|h|x Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-D [level] Print debug diagnostics to stderr
outfile Base name for input[ti2]/output[ti3] file
chartread -HELP (return code: 1)
Read Target Test Chart, Version 1.8.3
Author: Graeme W. Gill, licensed under the AGPL Version 3
usage: chartread [-options] outfile
-v Verbose mode
-c listno Set communication port from the following list (default 1)
1 = '/dev/ttyS0'
2 = '/dev/ttyS1'
3 = '/dev/ttyS10'
4 = '/dev/ttyS11'
5 = '/dev/ttyS12'
6 = '/dev/ttyS13'
7 = '/dev/ttyS14'
8 = '/dev/ttyS15'
9 = '/dev/ttyS16'
10 = '/dev/ttyS17'
11 = '/dev/ttyS18'
12 = '/dev/ttyS19'
13 = '/dev/ttyS2'
14 = '/dev/ttyS20'
15 = '/dev/ttyS21'
16 = '/dev/ttyS22'
17 = '/dev/ttyS23'
18 = '/dev/ttyS24'
19 = '/dev/ttyS25'
20 = '/dev/ttyS26'
21 = '/dev/ttyS27'
22 = '/dev/ttyS28'
23 = '/dev/ttyS29'
24 = '/dev/ttyS3'
25 = '/dev/ttyS30'
26 = '/dev/ttyS31'
27 = '/dev/ttyS4'
28 = '/dev/ttyS5'
29 = '/dev/ttyS6'
30 = '/dev/ttyS7'
31 = '/dev/ttyS8'
32 = '/dev/ttyS9'
-t Use transmission measurement mode
-d Use display measurement mode (white Y relative results)
-y l|c Other: l = LCD, c = CRT
-e Emissive for transparency on a light box
-p Measure patch by patch rather than strip
-x [lx] Take external values, either L*a*b* (-xl) or XYZ (-xx).
-n Don't save spectral information (default saves spectral)
-l Save CIE as D50 L*a*b* rather than XYZ
-L Save CIE as D50 L*a*b* as well as XYZ
-r Resume reading partly read chart
-I file.cal Override calibration info from .ti2 in resulting .ti3
-F filter Set filter configuration (if aplicable):
n None
p Polarising filter
6 D65
u U.V. Cut
-N Disable initial calibration of instrument if possible
-B Disable auto bi-directional strip recognition
-H Use high resolution spectrum mode (if available)
-X file.ccmx Apply Colorimeter Correction Matrix
-X file.ccss Use Colorimeter Calibration Spectral Samples for calibration
-Q observ Choose CIE Observer for CCSS instrument:
1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2
-T ratio Modify strip patch consistency tolerance by ratio
-S Suppress wrong strip & unexpected value warnings
-W n|h|x Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-D [level] Print debug diagnostics to stderr
outfile Base name for input[ti2]/output[ti3] file